首页|期刊导航|中华医学杂志(英文版)|Circulatory responses to nasotracheal intubation: comparison of GlideScope(R) videolaryngoscope and Macintosh direct laryngoscope

Circulatory responses to nasotracheal intubation: comparison of GlideScope(R) videolaryngoscope and Macintosh direct laryngoscope

XUE Fu-shan LI Xuan-ying LIU Qian-jin LIU He-ping YANG Quan-yong XU Ya-chao LIAO Xu LIU Yi

中华医学杂志(英文版)2008,Vol.20Issue(14):1290-1296,7.
中华医学杂志(英文版)2008,Vol.20Issue(14):1290-1296,7.

Circulatory responses to nasotracheal intubation: comparison of GlideScope(R) videolaryngoscope and Macintosh direct laryngoscope

Circulatory responses to nasotracheal intubation: comparison of GlideScope(R) videolaryngoscope and Macintosh direct laryngoscope

XUE Fu-shan 1LI Xuan-ying 2LIU Qian-jin 1LIU He-ping 3YANG Quan-yong 2XU Ya-chao 1LIAO Xu 1LIU Yi1

作者信息

  • 1. Department of Anesthesiology, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100144, China
  • 2. Xinxiang Medical College, Xinxiang, Henan 453003, China
  • 3. Department of Anesthesiology, Washington University, School of Medicine, 660 S. Euclid Ave, St. Louis, MO, USA
  • 折叠

摘要

Abstract

Background The GlideScope videolaryngoscope (GSVL) has been shown to have no special advantage over theMacintosh direct laryngoscope (MDL) in attenuating the circulatory responses to orotracheal intubation, but no study has compared the circulatory responses to nasotracheal intubation (NTI) using the two devices. This prospective randomized clinical study was designed to determine whether there was a clinically relevant difference between the circulatory responses to NTI with the GSVL and the MDL.Methods Seventy-six adult patients were randomly allocated equally to the GSVL group and the MDL group. After induction of anesthesia, NTI was performed. Non-invasive blood pressure (BP) and heart rate (HR) were recorded before induction (baseline values) and immediately before intubation (post-induction values), at intubation and every minute for a further five minutes. During the observation, times required to reach the maximum values of systolic BP (SBP) and HR, times required for recovery of SBP and HR to postinduction values and incidence of SBP and HR percent changes>30% of baseline values were also noted. The product of HR and systolic BP, I.e. Rate pressure product (RPP), and the areas under SBP and HR vs. Time curves (AUCSBP and AUCHR) were calculated.Results The NTI with the GSVL resulted in significant increases in BP, HR and RPP compared to postinduction values, but these circulatory changes did not exceed baseline values. BPs at all measuring points, AUCSBP, maximum values of BP and incidence of SBP percent increase>30% of baseline value during the observation did not differ significantly between groups. However, HR and RPP at intubation and their maximum values, AUCHR and incidence of HR percent increase > 30% of baseline value were significantly higher in the MDL group than in the GSVL group. -times required for recovery of SBP and HR to postinduction values were significantly longer in the MDL group than in the GSVL group.Conclusions The pressor response to NTI with the GSVL and the MDL was similar, but the tachycardiac response to NTI was lesser and of a shorter duration when using a GSVL than when using an MDL.

关键词

GlideScope(R) videolaryngoscope/Macintosh direct laryngoscope/nasotracheal intubation/circulatory responses/airway management

Key words

GlideScope(R) videolaryngoscope/Macintosh direct laryngoscope/nasotracheal intubation/circulatory responses/airway management

分类

医药卫生

引用本文复制引用

XUE Fu-shan,LI Xuan-ying,LIU Qian-jin,LIU He-ping,YANG Quan-yong,XU Ya-chao,LIAO Xu,LIU Yi..Circulatory responses to nasotracheal intubation: comparison of GlideScope(R) videolaryngoscope and Macintosh direct laryngoscope[J].中华医学杂志(英文版),2008,20(14):1290-1296,7.

中华医学杂志(英文版)

OACSTPCDMEDLINESCI

0366-6999

访问量0
|
下载量0
段落导航相关论文