天鹅型记忆加压接骨器记忆生物力学特性检测

苏佳灿 曹洪海 王瑞官 张春才 薛召军 吴建国 丁祖泉

中国临床康复2006,Vol.10Issue(5):182-184,3.
中国临床康复2006,Vol.10Issue(5):182-184,3.

天鹅型记忆加压接骨器记忆生物力学特性检测

Biomechanical feature measurement of Swan-like memory compression connector

苏佳灿 1曹洪海 1王瑞官 1张春才 1薛召军 2吴建国 2丁祖泉2

作者信息

  • 1. 解放军第二军医大学长海医院骨科,上海市,200433
  • 2. 同济大学生命科学与生物工程学院,上海市,200092
  • 折叠

摘要

Abstract

BACKGROUND: The biomechanical features of Swan-like memory compression connector designed for fractures in hemerus or the parts adjacent to joints are analyzed through biomechanical calculation and experimental measurements.OBJECTIVE: To analyze the relative memory biomechanieal significance through biomechanical measurement of Swan-like memory compression connectorDESIGN: Both biomechanieal calculation and the experimental measurement were conducted for mutual supplementation and confirmation SETTING: The Orthopaedic Department of Changhai Hospital Affiliated to Second Military Medical University of Chinese PLA and the Life Science and Tissue Engineering Institute of Tongji University MATERIALS: This experiment was conducted at the laboratory of Orthopaedic Department of Changhai Hospital Affiliated to Second Military Medical University of Chinese PLA and the Life Science and Tissue Engineering Institute of Tongji University between January 2001 and May 2003.Totally 20 hemerus from adult males who died of craniocerebral injury were chosen.METHODS: Humid hemerus from the adult corpse was chosen to prepare fracture. Encircling the prescale followed by fixation of Swan-like memory compression connector, then we measured the stress produced by compression part and encircle part at fixing the fracture.MAIN OUTCOME MEASURES: ①The stress of holding part; ② the stress of the compression part RESULTS: The stress range of holding part contacting with humerus was 2.42-22.68 N, and the stress in the fracture face, which was produced by compression part, was about 13.6 Mpa.CONCLUSION: The stress of holding part of Swan-like memory compression connector is useful in fixing the fracture parts of humerus, and the stress of compression part is suitable for the healing of fracture.

关键词

生物力学/记忆/图像处理,计算机辅助

分类

医药卫生

引用本文复制引用

苏佳灿,曹洪海,王瑞官,张春才,薛召军,吴建国,丁祖泉..天鹅型记忆加压接骨器记忆生物力学特性检测[J].中国临床康复,2006,10(5):182-184,3.

基金项目

解放军第二军医大学长海医院258资助项目(258-5)the Grants from the 258 Program of Changhai Hospital of the Second Military Medical University of Chinese PLA, No.258-5 (258-5)

中国临床康复

OA北大核心CSCDCSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文