The Clinical Study of Healon 5 in Phacoemulsification and IOL Implantation

Hui Yang Danying Zheng Jingjing Huang Yongsheng Huang Zhenping Zhang

眼科学报2001,Vol.17Issue(3):186-190,5.
眼科学报2001,Vol.17Issue(3):186-190,5.

The Clinical Study of Healon 5 in Phacoemulsification and IOL Implantation

The Clinical Study of Healon 5 in Phacoemulsification and IOL Implantation

Hui Yang 1Danying Zheng 1Jingjing Huang 1Yongsheng Huang 1Zhenping Zhang1

作者信息

  • 1. Zhongshan Ophthalmic Center, Sun Yat-sen University of Medical Sciences, Guangzhou 510060, China
  • 折叠

摘要

Abstract

Purpose: To compare a new ophthalmic viscoelastic device (OVD) Healon 5 with twoother kinds of OVDs commonly used in China during phacoemulsification and intraocularlens (IOL) implantation in terms of removal time, intraocular pressure, corneal andanterior chamber response.Methods: This prospective randomized study, in which patients and observers aremasked, comprises niety eyes. They were randomly divided into 3 groups with differentOVDs. Healon 5 (sodium hyaluronate 5 000 2.3 % ) was compared with Healon GV(sodium hyaluronate 7 000 1.4 % ) and Iviz (sodium hyaluronate 1.0 % ) . Thesurgeries were performed with temporal corneal incision, phacoemulsification in situ andfoldable lens intracapsular implantation. The characteristic and the removal time of theviscoelastic material as well as the postoperative IOP, corneal reaction and anteriorchamber reactions of the eyes were observed preoperatively and 24 hrs postoperatively.Exclusion criteria were glaucoma, a preoperative dilated pupil diameter smaller than 5.0mm, proliferative diabetic retinopathy, significant corneal pathology or a history ofuveitis.Results: The removal time was 47.42 ± 13.09 seconds in Healon 5, 16. 50 ± 5.45 inHealon GV and 15.83±7.40 in Iviz. The removal time of Healon 5 group wassignificantly longer than that of the other groups ( P =0. 000) . There is no significantIOP change 24 hours postoperatively and the difference of intraocular pressure amongthree groups was not significant ( P > 0.05). Healon 5 group had the slightest cornealand anterior chamber response, followed by Healon GV and Iviz.Conclusion: Although takes longer time to remove, Healon 5 is an ideal viscoelasticmaterial for its superior space maintenance capacity and high dispersity which providessuperior protection of endothelial cells compared to Healon GV and Iviz.

关键词

viscoelastic material/phacoemulsification/IOL implantation

Key words

viscoelastic material/phacoemulsification/IOL implantation

分类

医药卫生

引用本文复制引用

Hui Yang,Danying Zheng,Jingjing Huang,Yongsheng Huang,Zhenping Zhang..The Clinical Study of Healon 5 in Phacoemulsification and IOL Implantation[J].眼科学报,2001,17(3):186-190,5.

眼科学报

OAMEDLINE

1000-4432

访问量0
|
下载量0
段落导航相关论文