Accuracy and Electromagnetic Safety Evaluation of a Portable Electromagnetic Localization System for Micro Invasive Medical Devices in Vivo

LI Hong-wei YAN Guo-zheng JIANG Ping-ping

东华大学学报(英文版)2009,Vol.26Issue(2):189-194,6.
东华大学学报(英文版)2009,Vol.26Issue(2):189-194,6.

Accuracy and Electromagnetic Safety Evaluation of a Portable Electromagnetic Localization System for Micro Invasive Medical Devices in Vivo

Accuracy and Electromagnetic Safety Evaluation of a Portable Electromagnetic Localization System for Micro Invasive Medical Devices in Vivo

LI Hong-wei 1YAN Guo-zheng 1JIANG Ping-ping1

作者信息

  • 1. 20 Institute, Department of Instrument Science & Engineering, Shanghai Jiaotong University, Shanghai 200240, China
  • 折叠

摘要

Abstract

Aiming at localizing the telemetric capsule for detecting gastrointestinal physiological parameters in vivo accurately, a portable alternating current ( AC ) electromagnetic localization system is designed. To verify the feasibility of the method, the model and construction of the localization system are detailed. And static and dynamic accuracy of the localization system are tested by experiments. Next, we compare the simulating results of the electromagnetic radiation aroused by the localization system with the electromagnetic safety standards of human (ICNIRP guidelines and IEEE standard C95. 1 - 1991).Finally, in terms of the results of the static and dynamic experiments, conclusions are drawn that the accuracy of portable positioning system is high (less than 10 mm)enough to satisfy the localization need of the micro invasive medical devices in vivo, and there is no harm of electromagnetic radiation to human.

关键词

electromagnetic localization/portable/micro medical devices/in vivo/electromagnetic safety

Key words

electromagnetic localization/portable/micro medical devices/in vivo/electromagnetic safety

分类

信息技术与安全科学

引用本文复制引用

LI Hong-wei,YAN Guo-zheng,JIANG Ping-ping..Accuracy and Electromagnetic Safety Evaluation of a Portable Electromagnetic Localization System for Micro Invasive Medical Devices in Vivo[J].东华大学学报(英文版),2009,26(2):189-194,6.

基金项目

National Natural Science Foundation of China (NSFC) (No. 30570485) (NSFC)

National High Technology Research and Development Program of China (863) (No. 2006AA04Z368):Natural Science Foundation of Shanghai. China (No.06ER1406) (863)

东华大学学报(英文版)

1672-5220

访问量0
|
下载量0
段落导航相关论文