中国组织工程研究与临床康复2008,Vol.12Issue(1):193-195,3.
金属托槽重复利用的抗剪切强度
Shear bond strength of recycled metal brackets
刘新强 1李正明 2马长柏 1张丁 3孙志辉3
作者信息
- 1. 青岛大学医学院附属医院口腔正畸科,山东省青岛市,266003
- 2. 深圳市南山区人民医院口腔科,广东省深圳市,518052
- 3. 北京大学口腔医学院正畸科,北京市,100081
- 折叠
摘要
Abstract
BACKGROUND: Bracket dropping is often seen in clinic. Can these shed brackets be used again; what should be done to treat these brackets; is the bond strength of these recycled brackets different from those new ones, these questions are often concerned by orthodontists in their clinic and are the purpose of our study as well.OBJECTIVE: To evaluate the shear bond strength and compare two base-cure methods of recycled brackets. DESIGN: Grouping control study. SITTING: Department of Orthodontics, the Affiliated Hospital of Medical College, Qingdao University; Department of Materials, Dental School, Beijing University. MATERIALS: The teeth were collected from Oral Surgery, the Affiliated Hospital of Medical College, Qingdao University. The age was from 11 to 19 years. The gender was half male and half female. Intact enamel of the crown was required, but decayed, fracture, tetracycline pigmentation teeth or fluorosis teeth were excluded. Patients provided the confirmed consent for this experiment.METHODS: The experiment was carried out in Stomatology College of Peaking University in December 2005. Thirty ex vivo teeth were selected randomly from those prepared enamel surfaces, used as sample for rebounding. The edgewise brackets of swallow-tailed brackets were bonded on each tooth and rebonded after 24 hours. The teeth were cleaned and divided randomly into 3 groups. There were 10 teeth in each group. Group 1 was bonded with new brackets; group 2 with recycled brackets whose adhesive remnant were burned and got rid of; group 3 with recycled brackets whose adhesive remnant in the groove of the base were stored. Bracket was provided by Standard edgewise, Orsu Company, Hangzhou, China. After 24 hours, the shear bond strength was tested with material testing machine (Autogragh, Shimadzu, Japan). Adhesive remnant index (ARI) was added up. MAIN OUTCOME MEASURES: Shear strength of old metal bracket after rebonding and adhesive remnant.RESULTS: ① Shear bond strength: The shear bond strengths were (10.094±3.158 9) in group 1, (10.266±2.406 0) in group 2 and (8.898±1.365 9) in group 3. There were no statistically significant differences among the three groups (P > 0.05). ② ARI scores: ARI scores were 51.7%, 58.3% and 35.0% in the three groups, respectively. There were statistically significant differences between group 2 and 3. CONCLUSION: In vitro study indicates that the recycled metal brackets can reach good bond strength and that maybe there is chemical bond between new and old adhesive.关键词
粘结/托槽/剪切强度分类
医药卫生引用本文复制引用
刘新强,李正明,马长柏,张丁,孙志辉..金属托槽重复利用的抗剪切强度[J].中国组织工程研究与临床康复,2008,12(1):193-195,3.