| 注册
首页|期刊导航|中国药房|高效液相色谱法测定人血清中5-氟尿嘧啶的浓度

高效液相色谱法测定人血清中5-氟尿嘧啶的浓度

姚水宝 杨水新

中国药房2001,Vol.12Issue(4):227-228,2.
中国药房2001,Vol.12Issue(4):227-228,2.

高效液相色谱法测定人血清中5-氟尿嘧啶的浓度

Determination of Fluorouracil in Human Serum With HPLC

姚水宝 1杨水新1

作者信息

  • 1. 浙江省湖州市中心医院,
  • 折叠

摘要

Abstract

OBJECTIVE: To determine the content of 5-Fu in human serum.METHODS: Serum protein was precipitated with trichloroacetic acid .HPLC was used for determination of 5-Fu .The column was Shimpack CLC C18(150 × 6mm, 5μm)with YWG for protection.The mobile phase was 0.25% KH2PO4-acetonitrile(98: 2, pH7.0) .The flow rate was 1ml/min.The detection wavelength was 265nm.Two standard curves were made in the concentrations of 0.195~6.250μg/ ml and 6.25~200.00μg/ml, respectively.RESULTS: The calibration curves revealed linearity in the range of 0.195~200μg/ml.The with-in-day recoveries and RSDs of 5-Fu at 0.8, 4, 20 and 100μg/ ml concentration points were 104. 88%, 1.95%; 104.58%,1.38%; 101.40%, 0.39%and 99.14%, 0.37%, and the between-day recoveries and RSDs of 5-Fu were 105.12%, 2.02%;106.30 %, 0.78 %; 100.60 %, 0.65 % and 99.38 %, 0.92 % respectively. CONCLUSION: This method is rapid, accurate and suitable for pharmacokinetical study and conventional monitoring of 5-Fu.

关键词

5-氟尿嘧啶/高效液相色谱/血药浓度

分类

医药卫生

引用本文复制引用

姚水宝,杨水新..高效液相色谱法测定人血清中5-氟尿嘧啶的浓度[J].中国药房,2001,12(4):227-228,2.

中国药房

1001-0408

访问量0
|
下载量0
段落导航相关论文