| 注册
首页|期刊导航|分析化学|流动注射化学发光测定甲基对硫磷

流动注射化学发光测定甲基对硫磷

饶志明 王建宁 李隆弟 张新荣

分析化学2001,Vol.29Issue(4):373-377,5.
分析化学2001,Vol.29Issue(4):373-377,5.

流动注射化学发光测定甲基对硫磷

Determination of Methyl-parathion Using Luminol-based Chemiluminescence Flow Injection Method

饶志明 1王建宁 1李隆弟 1张新荣1

作者信息

  • 1. 清华大学化学系,
  • 折叠

摘要

Abstract

A simple, fast flow injection chemiluminescence (CL) method for the determination of methyl-parathion has been developed. It is based on the reaction of methyl parathion with luminol-H2O2 in the alkaline medium (pH:11.5~12.0), sensitized by water-soluble macromolecule Polyethylene glycol 400. Under the optimal conditions, the CL intensity was linear to the concentration in the range of 5.0×10-8~1.0×10-5 g/mL (r=0.9996), with a detection limit (3σ) of 2.0×10-8 g/mL. Relative standard deviation was less than 4% (n=11) and the recovery was between 82%~93%. This method has been successfully applied to the determination of trace residue of methyl-parathion in grain sample.

关键词

化学发光,流动注射,甲基对硫磷,聚乙二醇-400

分类

化学化工

引用本文复制引用

饶志明,王建宁,李隆弟,张新荣..流动注射化学发光测定甲基对硫磷[J].分析化学,2001,29(4):373-377,5.