| 注册
首页|期刊导航|湖南大学学报(自然科学版)|A Simplified Method to Calculate the Wet Bulb Globe Temperature(WBGT)

A Simplified Method to Calculate the Wet Bulb Globe Temperature(WBGT)

ZHANG Lei MENG Qing-lin ZHAO Li-hua ZHANG Yu-feng

湖南大学学报(自然科学版)2009,Vol.36Issue(z1):40-44,5.
湖南大学学报(自然科学版)2009,Vol.36Issue(z1):40-44,5.

A Simplified Method to Calculate the Wet Bulb Globe Temperature(WBGT)

A Simplified Method to Calculate the Wet Bulb Globe Temperature(WBGT)

ZHANG Lei 1MENG Qing-lin 1ZHAO Li-hua 1ZHANG Yu-feng1

作者信息

  • 1. State Key Laboratory of Subtropical Building Science,South China University of Technology,Guangzhou,Guangdong 510640,China
  • 折叠

摘要

Abstract

Wet bulb globe temperature(WBGT) is a comprehensive index obtained mainly from three pa-rameters:black globe temperature(Tg),wet bulb temperature(Tw),and dry bulb temperature(Ta).While in field observation and numerical simulation,black globe temperature and wet bulb temperature were not easy to obtain, so WBGT was difficult to measure and calculate directly.In order to solve this problem,air dry bulb temperature, wet bulb temperature,globe temperature,relative humidity,mean air velocity,solar radiation and wet bulb globe temperature were collected during the summer(July)in Guangzhou.Correlation analysis and regression analysis were used to get a simplified method to calculate WBGT.The results showed that dry bulb temperature,relative humidity,solar radiation and WBGT were interrelated to some extent.These three pa-rameters could be used in the simplified method to predict WBGT,and the linear correlation and precision of this model were high.In addition,we used the measured data to verify the simplified method,and the results showed that the error of the calculated value and the measured value was all below 5%,which means the simpli-fied calculating method is feasible and can be used in field observation and simulation research of urban thermal environment.

关键词

hot and humid regions/urban thermal environment/wet bulb globe temperature/multivariate linear regression

Key words

hot and humid regions/urban thermal environment/wet bulb globe temperature/multivariate linear regression