Abstract
In view of the leakage of mechanical face seal used in the frequency starting sulfuric acid pump, the reasons of failure was analyzed, then reformation scheme was proposed, the final the short-term failure of mechanical face seal was resolved.关键词
频繁启动/机械密封/失效分析/改造Key words