The UHV magnetic-valve controllable parallel reactor(MVCR) adopts auto-disturbance rejection disperse arithmetic,which can produce favorable regulation characteristics and improve UHV AC transmission power, system stability and the quality of power supply. This paper adopts auto-disturbance rejection controller of floating point DSP TMS320F28335 as its hardware-in-the-loop simulation device and MATLAB2008A to model and simulation and real-time control for UHV transmission system .Test results show that the control algorithm is adaptive to the magnetic valve-controlled parallel reactor complex nonlinear control features,moreover, it is in response to high-speed reactive power requirements in the UHV lines.Theoretical analysis predicts the regulation of UHV magnetic-valve controllable parallel reactor controller under different load characteristics and full compensation conditions, meanwhile ,it provides theory foundation for this device project.关键词
特高压/磁阀/可控电抗器/DSP/自抗扰控制Key words
UHV/magnetic-valve/controllable reactor/DSP/auto-disturbance rejection controller分类
信息技术与安全科学引用本文复制引用