广东医学2001,Vol.22Issue(6):480-481,2.
气道狭窄患者置入金属支架后的肺功能变化
The effect of tracheal and bronchial metal stent placement on pulmonary function in patients with tracheobronchial stenosis
摘要
Abstract
Objective To evaluate the effect of metal stent placement on pulmonary function in patients with tracheobronchial stenosis. Methods 16 patients with tracheobronchial tumors and 12 patients with tracheobronchial tuberculosis placed with Ultraflex stents or Pulmaz stents were studied. Pulmonary function values were compared before, immediately after (48h) and sometime after (about 3 months) operation in 28 patients. Results Before treatment, airflow was severely impaired in all patients. All spirometric parameters increased significantly following operation. In particular FVC, FVC%, FEV1, FEV1%,PEF,TLC,TLC%,VC and VC% improved dramatically in all patients. Conclusion Pulmonary function test may be helpful in assessing the efficacy of tracheobronchial metal stent placement in patients with tracheobronchial stenosis.关键词
气道金属支架/肺癌/支气管内膜结核/肺功能分类
医药卫生引用本文复制引用
王首红,陈正贤,高兴林,郭纪全,张伟,李静,廖小兰,赖倩..气道狭窄患者置入金属支架后的肺功能变化[J].广东医学,2001,22(6):480-481,2.基金项目
本课题系广东省卫生厅资助项目(编号:A1997019) (编号:A1997019)