王进 黄廷琳

中国防痨杂志2001,Vol.23Issue(1):52-53,2.
中国防痨杂志2001,Vol.23Issue(1):52-53,2.

2946份痰标本抗酸杆菌检查结果与咳痰时间的关系

The relatonship between the examine results of acid-fast basillus of the sputum collected in different time in 2936 specimens

王进 1黄廷琳1

作者信息

  • 1. 湖北省宜昌县防疫站结防科
  • 折叠

摘要

Abstract

Objective To evaluate the influence of the sputum collected in different time on the determination of acid-fast bacillus.Methods The sputum specimens were dyed with the Ziehl-Neelsen anti-acid dyeing method,and observed with the microscope.The positive rate and the distributing of various sputum time are studied.Results The positive rate of 2 946 sputum specimens varies evidently in the morning,at night,or any time.The distributing of 462 smear positive in the morning,at night,or any time have great importance.Conclusion The sputum collected in different time has a great influence on the positive rate of acid-fast bacillus.The determination of morning sputum should be emphasized.

关键词

结核,肺/显微镜检查/抗酸杆菌

分类

医药卫生

引用本文复制引用

王进,黄廷琳..2946份痰标本抗酸杆菌检查结果与咳痰时间的关系[J].中国防痨杂志,2001,23(1):52-53,2.