| 注册
首页|期刊导航|广东电力|珠江发电厂机组汽水品质超标的原因分析

珠江发电厂机组汽水品质超标的原因分析

罗彤

广东电力2001,Vol.14Issue(2):59-60,67,3.
广东电力2001,Vol.14Issue(2):59-60,67,3.

珠江发电厂机组汽水品质超标的原因分析

Cause analysis of overproof steam-water quality of Zhujiang Power Plant units

罗彤1

作者信息

  • 1. 珠江发电厂,
  • 折叠

摘要

Abstract

The steam-water quality of the generating units in Zhujiang PowerPlant experiences overproof H-ion exchanging conductivity. Based on analysis of steam-water quality, it is found that the problem is mainly caused by insufficient tightness of the turbine vacuum system and inadequate opening of the deaerator exhaust valve. Measures for ensuring the proof steam-water quality are proposed at last.

关键词

氢离子交换电导率/二氧化碳/分配系数

分类

信息技术与安全科学

引用本文复制引用

罗彤..珠江发电厂机组汽水品质超标的原因分析[J].广东电力,2001,14(2):59-60,67,3.