Abstract

Micromachining of capillary electrophoresis chips is described.The current in channels was determined versus the voltage applied on the chip.Using laser-induced fluorescence detection,the process of injection and separation on chips was recorded with charge-coupled device(CCD).With defferent voltge of reservoirs on glass chips,profiles of the sample plug were studied. The elctropherogram of hydrolysis product of fluorescein isothiocyanate (FTTC-OH) and arginine labeled by fluorescein isothiocyante(FTTC-Arg) was obtained.