范宇 陈学兵

压力容器2009,Vol.26Issue(7):61-63,3.
压力容器2009,Vol.26Issue(7):61-63,3.DOI:10.3969/j.issn.1001-4837.2009.07.013

硫酸装置冷却器换热管的检验和现场修复

Inspection and Repair of a Heat Exchange Cooler in Suphric Acid Process

范宇 1陈学兵2

作者信息

  • 1. 合肥通用机械研究院,安徽,合肥,230031
  • 2. 中石化长岭分公司,湖南,岳阳,414012
  • 折叠

摘要

Abstract

As the first set of device imported from Danmark that produce suphric acid by wet acid gas. This paper deals with the problem of leakage in the operation of the device that use the Topsoe technolo-gy. We inspect the tube by a special magnetic particle examination and ultrasonic examination and solve the problem of leakage.

关键词

托普索WSA制硫酸装置/检验/泄漏

Key words

WSA produce suphfic acid / inspection/ leakage