热力发电2009,Vol.38Issue(7):69-71,3.DOI:10.3969/j.issn.1002-3364.2009.07.069
凝汽器循环水系统节能节水优化改造
RETROFIT FOR OPTIMIZING THE CONSERVATION OF ENERGY AND WATER IN CIRCULATING WATER SYSTEM
谭旭东 1王中伟1
作者信息
- 1. 华能威海发电有限责任公司,山东威海264205
- 折叠
摘要
Abstract
The problems existing in circulating water system of condenser for unit no. 1 in Huaneng Weihai Power Plant, such as the large allowance of output capacity for the circulating water pump, lower efficiency of the said pump, the air accumulation in water chamber of the condenser, as well as greater consumption of fresh water used for lubricating the water pump, etc. ,affect economic efficiency of the unit in operation. After optimized technical retrofit carried out for the circulating water system, the unit can additionally generate electric power about 500 kW in summer,can save service power for circulating water pump about 150 kW in winter,the daily average-water saving being 400 t.关键词
125 MW机组/凝汽器/循环水泵/变频调速/节能节水Key words
125 MW unit/condenser/circulating water pump/frequency converting speed regulation/energy and water-saving分类
能源科技引用本文复制引用
谭旭东,王中伟..凝汽器循环水系统节能节水优化改造[J].热力发电,2009,38(7):69-71,3.