福州大学学报(自然科学版)2001,Vol.29Issue(1):90-92,3.
液固传质系数和催化剂包内液体流速的测定
Measurements of liquid-solid mass transfer coefficient and liquid flow-rate within catalyst capsule
摘要
Abstract
The liquid-solid mass transfer coefficients and liquid flow-ratewithin the catalyst capsule have been measured in a countercurrent flow column by this study. The measurements were completed under the temperature 25℃ and the normal pressure in a glass column with the diameter 56mm and the catalyst-bed-height 528mm. The correlations for calculation of the liquid-solid mass transfer coefficients and liquid flow-rate within the catalyst capsule were obtained by regressing the experimental data, which can be applied to simulate the catalytic distillation process for the hydrolysis of the methyl acetate.关键词
催化精馏/液固传质/液体流速分类
化学化工引用本文复制引用
王良恩,邱挺,吴燕翔,赵之山..液固传质系数和催化剂包内液体流速的测定[J].福州大学学报(自然科学版),2001,29(1):90-92,3.