人工晶状体前表面非球面化改良能够改善视觉质量OA
Improving quality of vision with an anterior surface modified prolate intraocular lens: A prospective clinical trial
目的:根据对比敏感度结果比较前表面改良的非球面Tecnis Z9000 IOL和标准的911A IOL的光学性能.方法:Tecnis Z9000硅凝胶IOL和911A IOL具有共同的基本特征包括12mm总长度、三片直边双凸6mm的光学直径和成角的聚丙乙烯C襻.对连续10例双侧白内障患者(20眼)进行了随机前瞻研究,所有患者都接受了白内障超声乳化手术并随机于1眼植入Tecnis Z9000IOL,另1眼在术后6wk内植入911A IOL作为对照,…查看全部>>
· AIM: To compare the optical performance of the anterior surface modified prolate Tecnis Z9000 IOL with the standard 911A IOL in terms of contrast sensitivity outcomes.· METHODS: The Tecnis Z9000 silicone IOL shares the same basic characteristics with the 911A IOL including a 12.0mmoverall diameter, 3-piece equiconvex 6.0mm optic and angulated cap C polyvinylidene fluoride haptics. This is a randomized prospective study that involved ten consecutive patient…查看全部>>
Subrayan;E.;Mavrikakis;J.;A.;Bell
马来西来吉隆坡,马来亚大学医学院眼科英国肯特郡,Royal Tunbridge Wells激光眼科诊所
医药卫生
Tecnis Z9000 IOL911A IOL对比敏感度超声乳化术
Tecnis Z9000 911A IOL contrast sensitivityphacoemulsification
《国际眼科杂志》 2007 (4)
918-920,3