热科学学报(英文版)2006,Vol.15Issue(1):92-96,5.
Oscillatory Flow in Thermoacoustic Sound Wave Generator
Oscillatory Flow in Thermoacoustic Sound Wave Generator
Masayasu HATAZAWA1
作者信息
- 1. Department of Engineering Science, Junior College of Nihon University, 7-24-1, Narashinodai,Funabashi-city, Chiba, 274-8501, Japan
- 折叠
摘要
Abstract
Oscillatory flow in a thermoacoustic sound wave generator is described. The thermoacoustic sound wave generator plays an important role in thermoacoustic equipment. The heat exchange between the working fluid and the stack, the acceleration and deceleration of the working fluid and viscous friction loss both in the stack and in the resonance tube influence the performance of the thermoacoustic sound wave generator. Particularly,oscillatory flow significantly influences the heat exchange mechanism between the working fluid and the stack.Temporal changes in pressure and velocity are sinusoidal inside the resonance tube. Flow forms an oscillatory jet just behind the tube outlet, and becomes intermittent far downstream outside the resonance tube. The open-end corrections of 0.63R, that is, the region where oscillatory flow characteristics are maintained downstream in spite of being outside the tube outlet, are confirmed by velocity measurements and flow visualization. Also, they are almost equal to acoustical theoretical results.关键词
thermoaeoustic phenomena/sound wave generator/oscillatory flowKey words
thermoaeoustic phenomena/sound wave generator/oscillatory flow分类
能源科技引用本文复制引用
Masayasu HATAZAWA..Oscillatory Flow in Thermoacoustic Sound Wave Generator[J].热科学学报(英文版),2006,15(1):92-96,5.