| 注册
首页|期刊导航|中华医学杂志(英文版)|Clinical and radiographic results of cervical artificial disc arthroplasty: over three years follow-up cohort study

Clinical and radiographic results of cervical artificial disc arthroplasty: over three years follow-up cohort study

TIAN Wei HAN Xiao LIU Bo LI Qin HU Lin LI Zhi-yu YUAN Qiang HE Da XING Yong-gang

中华医学杂志(英文版)2010,Vol.123Issue(21):2969-2973,5.
中华医学杂志(英文版)2010,Vol.123Issue(21):2969-2973,5.DOI:10.3760/cma.j.issn.0366-6999.2010.21.003

Clinical and radiographic results of cervical artificial disc arthroplasty: over three years follow-up cohort study

Clinical and radiographic results of cervical artificial disc arthroplasty: over three years follow-up cohort study

TIAN Wei 1HAN Xiao 1LIU Bo 1LI Qin 1HU Lin 1LI Zhi-yu 1YUAN Qiang 1HE Da 1XING Yong-gang1

作者信息

  • 折叠

摘要

Abstract

Background Theoretic advantages of cervical disc arthroplasty include preservation of normal motion and biomechanics in the cervical spine, and reduction of adjacent-segment degeneration. The clinical and radiographic effects of cervical disc arthroplasty in short term have been ascertained. The aim of this study is to research the data of mid-term results.Methods In this prospective cohort study, 50 patients who underwent cervical disc arthroplasty from December 2003 to January 2006 were enrolled. There were 39 patients who received 1-level disc arthroplasty, and 11 patients received 2-level disc arthroplasty, with an average age of 50.9 years (range from 29 to 73). The median follow-up was 41.85months (range from 36.00-55.63 months). Patients were followed prospectively with respect to their symptoms,neurologic signs, and radiographic results.Results The median value of Japanese Orthopaedic Association (JOA) score was 14.0 before surgery, and 16.5 at the most recent follow-up (P <0.01). The median value of the recovery rate of the JOA score was 92.2%. The preoperative range of motion (ROM) at the indexed level was (10.40±4.97)°, which has significantly correlated with the most recent follow-up ROM which was (8.56±4.76)° (P <0.05, r=0.33). The ROM at the operative level at the most recent follow-upwas greater than the value at the 3-month follow-up of (7.52±3.37)° (P <0.05). The preoperative functional spinal unit (FSU) angulation was (-0.96±6.52)°, which was not significantly correlated with that of the most recent follow-up value of (-2.65±7.95)° (P <0.01, r=0.53). The preoperative endplate angulation was (2.61±4.85)°, which had no significant correlation with that of the most recent follow-up value of (0.71±6.41)° (p >0.05).Conclusions The clinical and radiographic results of cervical disc arthroplasty are good in mid-term follow-up. The normal range of motion of the operated level and the biomechanics in the cervical spine are well preserved.

关键词

cervical disc arthroplasty/cervical spondylosis/cervical disc herniation

Key words

cervical disc arthroplasty/cervical spondylosis/cervical disc herniation

分类

医药卫生

引用本文复制引用

TIAN Wei,HAN Xiao,LIU Bo,LI Qin,HU Lin,LI Zhi-yu,YUAN Qiang,HE Da,XING Yong-gang..Clinical and radiographic results of cervical artificial disc arthroplasty: over three years follow-up cohort study[J].中华医学杂志(英文版),2010,123(21):2969-2973,5.

基金项目

This work was supported by Beijing Municipal Science &Technology Commission Special Research Project (No.Z080003032208013). (No.Z080003032208013)

中华医学杂志(英文版)

OACSCDCSTPCDMEDLINESCI

0366-6999

访问量0
|
下载量0
段落导航相关论文