煤田地质与勘探2011,Vol.39Issue(1):64-67,4.DOI:10.3969/j.issn.1001-1986.2011.01.015
工作面底板变形与破坏电阻率特征
Resistivity characteristic of deformation and failure of floor in workface
张朋 1王一 2刘盛东 3汪志军1
作者信息
- 1. 中国矿业大学深部岩土力学与地下工程国家重点实验,江苏,徐州,221008
- 2. 中国矿业大学资源与地球科学院,江苏,徐州,221008
- 3. 山西国阳新能股份有限公司,山西,阳泉,045000
- 折叠
摘要
Abstract
Through the establishment of geophysical numeric model of rock deformation and failure of coal floor in mining, the characteristics of resistivity variation of destruction zone in coal floor were analyzed by using forward calculation, WBD field monitoring was carried out in the workfaee of No.5 coal mine. Simulation data and field detection results show that the coal floor resistivity value is closely related with the mining process. High resistivity anomalies appeared behind the workface, the high resistivity anomalies corresponded with the location of deformation and failure of floor. In front of workface low resistivity anomalies appeared, and coincided with the high stress area caused by mine pressure. Along with advance of workface, the resistivity anomalies will be synchronously changed. According to the regularities of floor rock resistivity change, and combined with the hydrogeology characteristics, the dynamic exploration of resistivity method can study the regularities of coal floor deformation and failure and is useful to predict water inrush in floor.关键词
采矿工程/底板破坏/电阻率法勘探/正演模拟/并行电法Key words
mining engineering/ deformation and failure of floor/ resistivity method/ forward modeling/ WBD分类
天文与地球科学引用本文复制引用
张朋,王一,刘盛东,汪志军..工作面底板变形与破坏电阻率特征[J].煤田地质与勘探,2011,39(1):64-67,4.