脱硫系统投运对吸风机运行的影响原因及预防措施
Impact of Desulfurization System to the Operation of Induced Draft Fan and Preventive Measures
孟鑫 1赵蓟玉 2马玥珺1
作者信息
- 1. 河北工程大学,河北邯郸,056021
- 2. 天津大唐盘山发电有限责任公司,天津,301900
- 折叠
摘要
Abstract
After the installation of desulfurization system in power plant ,because of the changes of the flue system, the absorption characteristics of air-conditioning have great influence, so the operation appear a security risk. In this paper, the operating conditions of induced draft fan was compared, that desulfurization system was putted into operation before and after, according to induced draft fan stall anomalies, analyses the causes that the impact on suction fan characteristics after desulfurization system be put into operation , and proposed preventive measures.关键词
脱硫系统/吸风机/电厂Key words
desulfurization system/ induced draft fan/power plant分类
机械制造引用本文复制引用
孟鑫,赵蓟玉,马玥珺..脱硫系统投运对吸风机运行的影响原因及预防措施[J].流体机械,2011,39(1):52-54,3.