黑龙江科技学院学报2011,Vol.21Issue(1):61-63,3.
瓦斯抽放管路流量测量的涡街流量计设计
Improvement of vortex flowmeter to measure gas flow in gas drainage pipeline
摘要
Abstract
This paper is an attempt to improve the K-factor of vertex flowmeter which stays constant only in a narrow scope, with a resulting restraint of the measurement range.The paper features the vortex flowmeter improved by adopting a nonlinear modified method of K-factor.Experiments indicate that the improved vortex fiowmeter boasts the measurement range of 6.05 ~497.79 L/h and the linearity of 1.111%.The improved vortex fiowmeter allows the measurement range to be effectively increased, with ensured accuracy and promises to come into use in the mine gas drainage pipeline.关键词
涡街流量计/瓦斯抽放/仪表系数/非线性修正Key words
vortex flowmeter/ gas drainage/ K-factor/ nonlinear modified分类
矿业与冶金引用本文复制引用
于洪仕..瓦斯抽放管路流量测量的涡街流量计设计[J].黑龙江科技学院学报,2011,21(1):61-63,3.基金项目
中国煤炭工业协会科学技术研究指导性计划项目(MTKJ2010-329) (MTKJ2010-329)