基于单周期控制PFC电流过零畸变分析
Input Current Distortion Analysis in Boost PFC Based on One Cycle Control
张先进 1宋永献1
作者信息
- 1. 淮海工学院,电子工程学院,江苏,连云港,222005
- 折叠
摘要
Abstract
Input current distortion in the vicinity of input voltage zero crossing of boost single phase power factor corrected (PFC) rectifier in high line frequency occurs. Current loop model and input admittance model of one cycle control PFC boost rectifier is presented. It is pointed that its equivalent power stage of current loop is a 1st order system, and its input admittance is pure resistive in low frequency domain and capacitive since 1 kHz around, then input current phase leads occurs. However, it is does not matter in aero ac power system with 400Hz or 360 ~ 800Hz line frequency,and is suitable for applications as front converter in aero power supply system.关键词
单向PFC/电流过零畸变/单周期控制/输入导纳Key words
single phase PFC/ current zero- crossing distortion/ one cycle control/ input admittance分类
信息技术与安全科学引用本文复制引用