| 注册
首页|期刊导航|中国组织工程研究与临床康复|Cobra枕颈内固定系统结合Halo-vest治疗颅颈交界区畸形效果

Cobra枕颈内固定系统结合Halo-vest治疗颅颈交界区畸形效果

郭亮兵 廖文胜 王利民 王卫东 谭鸿宇 鲍恒 刘屹林 董小通

中国组织工程研究与临床康复2011,Vol.15Issue(9):1594-1598,5.
中国组织工程研究与临床康复2011,Vol.15Issue(9):1594-1598,5.DOI:10.3969/j.issn.1673-8225.2011.09.018

Cobra枕颈内固定系统结合Halo-vest治疗颅颈交界区畸形效果

Effect of cobra internal fixation system combined with halo-vest on treatment of the craniocervical malformation

郭亮兵 1廖文胜 1王利民 1王卫东 1谭鸿宇 1鲍恒 1刘屹林 1董小通1

作者信息

  • 1. 郑州大学第一附属医院骨科,河南省郑州市450052
  • 折叠

摘要

Abstract

BACKGROUND: Craniocervical posterior fusion can decompress the spinal cord and obtain the early stability for the instability occipitocervical fusion. The anatomic design of Cobra system can provid strongly internal fixation for this instability fusion and it is beneficial for fixation, reduction and bone graft fusion with the Halo-vest external fixation.OBJECTIVE: To evaluate the clinical application of Cobra internal fixation system with Halo-vest in craniocervical fusion surgery for craniocervical region malformation patients.METHODS: Thirty-four cases of craniocervical region malformation underwent craniocervical fusion using Cobra internal fixation system and with a specific therapy used Halo-vest according to the actual situation. The JOA17 spinal cord function evaluation standard was used for evaluation of the treatment effect. The neurologic recovery rate was calculated by the method established by Yin Qing-shui. At 3, 6, 12, and 24 months after the internal fixation, two-plane roentgenograms, CT and 3D reconstruction could be made to judge the internal fixation and bone grafting fusion situation, some patient also did MRI to clarify the spinal cord decompression.RESULT AND CONCLUSION: All of the patients were followed up for 7-29 months. There were no aggravations of the symptoms of spinal cord compression. The preoperative average spinal function was 8.2 and postoperative average was 14.8,respectively. The overall mean improvement was 75%. One patient died of cerebral infarction postoperatively. At the sixth month of follow-up, there were two cases with bone graft nonunions and absorption, two cases with the loosed occiput plate bolt, one case with the pulled out screws, one case with a nonhealing incision. The Halo-vest was used in ten cases for 3 to 4 months postoperatively. Other cases wore a cervical collar until the bone grafts were fused completely. It is suggested that Cobra internal fixation system offers a good biomechanical stability for craniocervical region fixation. lt's convenient for reduction and fixation during the operation along with the Halo-vest, and suitable for the treatment of craniocervical region malformation.

关键词

颅颈交界区畸形/枕颈内固定/枕颈融合/Halo-vest

分类

医药卫生

引用本文复制引用

郭亮兵,廖文胜,王利民,王卫东,谭鸿宇,鲍恒,刘屹林,董小通..Cobra枕颈内固定系统结合Halo-vest治疗颅颈交界区畸形效果[J].中国组织工程研究与临床康复,2011,15(9):1594-1598,5.

中国组织工程研究与临床康复

OACSCDCSTPCD

2095-4344

访问量3
|
下载量0
段落导航相关论文