中国药业2011,Vol.20Issue(5):36-37,2.
注射用水微生物含量与贮存温度、方式及时间的关系
Relationship of Microbial Content of Injection Water with Storage Temperature,Way and Time
陈树新 1莫玉芳 1蔡先东 1陈翠环1
作者信息
- 1. 广东省佛山市第一人民医院药剂科,广东,佛山,528000
- 折叠
摘要
Abstract
Objective To verify the relationship of microbial content of injection water with the storage temperature, way and time. Methods Refering to the microbial limit test described in the China Pharmacopeia 2010, the microbial content in injection water at different storage temperatures, ways and time were detected. Results The inverse relation was found between microbial content in injection water and the storage temperature while there was the proportional relation between microbial content in injection water and the storage time. High temperature and cycle storage way could effectively inhibit microbial growth in injection water. Conclusion When the storage temperature, way and time are consistent with the requirement of FDA and GMP, which can effectively inhibit microbial growth in injection water and ensure the quality of injection water and prepared products.关键词
注射用水/微生物限度/贮存/温度/时间分类
医药卫生引用本文复制引用
陈树新,莫玉芳,蔡先东,陈翠环..注射用水微生物含量与贮存温度、方式及时间的关系[J].中国药业,2011,20(5):36-37,2.