| 注册
首页|期刊导航|中华医学杂志(英文版)|Six-month clinical outcomes of Firebird 2TM sirolimus-eluting stent implantation in real-world patients with coronary artery diseases

Six-month clinical outcomes of Firebird 2TM sirolimus-eluting stent implantation in real-world patients with coronary artery diseases

GE Jun-bo ZHANG Feng QIAN Ju-ying GE Lei LIU Xue-bo ZHOU Jun

中华医学杂志(英文版)2011,Vol.124Issue(6):831-835,5.
中华医学杂志(英文版)2011,Vol.124Issue(6):831-835,5.DOI:10.3760/cma.j.issn.0366-6999.2011.06.006

Six-month clinical outcomes of Firebird 2TM sirolimus-eluting stent implantation in real-world patients with coronary artery diseases

Six-month clinical outcomes of Firebird 2TM sirolimus-eluting stent implantation in real-world patients with coronary artery diseases

GE Jun-bo 1ZHANG Feng 1QIAN Ju-ying 1GE Lei 1LIU Xue-bo 1ZHOU Jun1

作者信息

  • 1. Shanghai Institute of Cardiovascular Diseases, Zhongshan Hospital, Fudan University, Shanghai 200032, China
  • 折叠

摘要

Abstract

Background The Firebird 2TM sirolimus-eluting stent (Firebird 2 stent) is a second-generation sirolimus-eluting stent which has a cobalt-chromium alloy stent platform, a brand new bracket structure, and two layers of styrene-butylenes-styrene polymer coatings with better biocompatibility. The Firebird 2TM cObalt-Chromium alloy sirolimus-elUting Stent registry (FOCUS registry) aimed to evaluate the safety and efficacy of the Firebird 2 stent in patients with coronary artery disease in daily practice.Methods The FOCUS registry is a prospective, non-randomized, international multi-center, single-arm clinical registry.Between March 2009 and February 2010, 5084 patients receiving at least 1 Firebird 2 stent during daily clinical practice at 83 medical centers were enrolled.Results Of the 5084 patients enrolled in the registry, 5077 and 5058 were respectively available for 30 days and 6 months follow-up. The 30-day rate of major adverse cardiac events (MACE) was 1.20%, including 13 cardiac deaths, 46 non-fatal myocardial infarction (MI), and 6 target vessel revascularization (TVR). At 6 months follow-up, the rate of MACE was 1.80%. There were 32 cardiac deaths, 48 non-fatal MI, and 15 TVR. According to the Academic Research Consortium definition, definite/probable stent thrombosis (ST) occurred in 0.43% (22/5058) of patients, including 8 cases of acute ST, 11 subacute ST, and 3 late ST.Conclusion The Firebird 2 stent showed the promising efficacy and safety at 30 days and 6 months in a real-world population of patients with coronary artery diseases.

关键词

sirolimus-eluting stent/percutaneous coronary intervention/coronary artery disease/cobalt-chromium alloy

Key words

sirolimus-eluting stent/percutaneous coronary intervention/coronary artery disease/cobalt-chromium alloy