Abstract
A method for correctioin and elimination of interference from matrix and major elements in simultaneously determination of Ga, In, Ta, W and Mo in copper, lead and zinc ores by inductively coupled plasma-mass spectrometry was developed. Interferences from matrix and major elements on the determination were systemically studied. The results showed that 1) when the concentration of Cu or Pb in the sample solution was< 200 μg/mL, no interference from Zn on the determinatioin of the elements above was observed. 2) Cu with concentration of > 50 μ/mL in the solution caused the negative interference on the determination of Ga, In, Ta, W and Mo. 3) Pb with concentration of > 100 μ/mL produced the positive and negative interference on W and Mo, respectively, and the interference couled be eliminated by Sc-Re-La mixed internal standardization or matrix matching method. 4) Pb with concentration of> 20 μg/mL caused the positive interference on the determination of Tl and the interference could be effectively relieved or eliminated by selecting 203Tl as measurement isotope and using matrix matching method or correction coefficient method.关键词
微量元素/铜、铅、锌矿石/电感耦合等离子体质谱法/干扰消除分类
化学化工引用本文复制引用
熊英,吴赫,王龙山..电感耦合等离子体质谱法同时测定铜铅锌矿石中微量元素镓铟铊钨钼的干扰消除[J].岩矿测试,2011,30(1):7-11,5.基金项目