含能材料2011,Vol.19Issue(1):78-81,4.DOI:10.3969/j.issn.1006-9941.2011.01.018
发射药膛内两种燃速测试方法的比较
Two Methods to Test Gun Propellant Burning Rate in Gun Chamber
张江波 1张玉成 1李强 1严文荣 1闫光虎 1赵晓梅1
作者信息
- 1. 西安近代化学研究所,陕西,西安,710065
- 折叠
摘要
Abstract
In order to study the burning rules of gun propellant in gun chamber,feasibility of microwave interferometer testing and ordinary t esting was analyzed based on the classical interior ballistic theory, and a relative calculation method was proposed.p-t curves and muzzle velocity were considered as basic data by the ordinary testing method,however v-t curves was considered as basic data by the microwave interferometer testing method.The burning rate of gun propellant in gun chamber could be obtained by both methods.Results show that the calculated p-t curves are consistent with the p-t curves of testing.Under pressure between 80 MPa and 250 MPa,the range of burning rate is between 17 cm· s-1 and 29 cm· s-1 by ordinary testing method,and under pressure between 80 MPa and 250 MPa,the range between 8 cm· s-1 and 23 cm · s-1 by microwave interferometer testing method.The formula of gun propellant burning rate in gun chamber deviates far from the exponential function.The precision of microwave interferometer testing method is better than that of ordinary testing method.关键词
复合材料/发射药/燃速/炮口初速/微波测试方法Key words
composite materials/ gun propellant/ burning rate/ muzzle velocity/ microwave interferometer testing method分类
军事科技引用本文复制引用