| 注册
首页|期刊导航|火炸药学报|PBX巴西试验与直接拉伸试验的比较

PBX巴西试验与直接拉伸试验的比较

庞海燕 李明 温茂萍 蓝林刚 敬仕明

火炸药学报2011,Vol.34Issue(1):42-44,58,4.
火炸药学报2011,Vol.34Issue(1):42-44,58,4.

PBX巴西试验与直接拉伸试验的比较

Comparison on the Brazilian Test and Tension Test of the PBX

庞海燕 1李明 1温茂萍 1蓝林刚 1敬仕明1

作者信息

  • 1. 中国工程物理研究院化工材料研究所,四川,绵阳,621900
  • 折叠

摘要

Abstract

In order to investigate the effectiveness of indirect tensile strength of PBX obtained by Brazilian test,Brazilian test and direct tension were performed. The results show that indirect tensile strength and tensile strength are 3.60 MPa and 5.46 MPa by Brazilian test and tension test to PBX samples respectively, and the former was about 65 % of the latter. The analysis on the face cracks of PBX samples after Brazilian testing showed that initial cracking was out of the center of the PBX samples, maybe the off-center cracking or the stress concentration causing to crack, and that didn't satisfy the condition of the center cracking for Brazilian test. Considering the Brazilian test can't be used to characterize more exactly tensile strength of the PBX.

关键词

材料科学/PBX/巴西试验/直接拉伸试验/拉伸强度

Key words

material science/ PBX/ Brazilian test/ tension test/ tensile strength

分类

军事科技

引用本文复制引用

庞海燕,李明,温茂萍,蓝林刚,敬仕明..PBX巴西试验与直接拉伸试验的比较[J].火炸药学报,2011,34(1):42-44,58,4.

基金项目

国家自然科学基金资助(10832003) (10832003)

火炸药学报

OA北大核心CSCDCSTPCD

1007-7812

访问量0
|
下载量0
段落导航相关论文