湖南大学学报(自然科学版)2011,Vol.38Issue(4):36-40,5.
基于清洁度的冷凝器污垢监测方法研究
Condenser Fouling Monitoring Methods Based on Cleanliness
摘要
Abstract
Fouling coefficient is an important measure parameter of condenser performance, but it is affected by multi-factors, therefore judging the condenser water side of tube walls fouling based on coefficient would have a significant error. So this paper proposed the concept of degree of eleanliness, which allows us to analyze the influence of the air accumulated on the steam side、 the fouling on condenser water side of tube walls、and the tube bundle coefficient of condenser on the overall heat transfer coefficient of the condenser respectively. It can diagnose the condenser fouling more accurately and provide a basis for scheduling reasonable cleaning. Experimental results show the method can be more reliable than the T-S fuzzy model, thermal resistance method, RBF neural network model when the condenser pipe blockage or a larger amount of air leakage into the condenser or condenser operating mode parameters change rapidly.关键词
冷凝器/污垢监测/清洁度/管束布置/汽侧空气量Key words
condenser/ fouling monitoring/ cleanliness / tube bundle coefficient/ steam side with air accumulated分类
信息技术与安全科学引用本文复制引用
张莹,王耀南,文益民..基于清洁度的冷凝器污垢监测方法研究[J].湖南大学学报(自然科学版),2011,38(4):36-40,5.基金项目
国家自然科学基金资助项目(60775047) (60775047)
国家863计划资助项目(2007AA04Z244,2008AA04Z214) (2007AA04Z244,2008AA04Z214)
湖南省自然科学基金资助项目(10JJ5067) (10JJ5067)