Abstract
If the thresholds are set unreasonably,the fault diagnosis method based on signed directed graph may cause the fault is predicted incorrectly or ignored. In this paper, the model of fuzzy signed directed graph is presented, in which the three-stage SDG model is substituted by the five-stage SDG model, the parameter node is given the fuzzy membership, and the corresponding fuzzy reasoning algorithm is presented. Fuzzy SDG model and fuzzy SDG reasoning are introduced into a fault diagnosis example of atmospheric and vacuum distillation unit,which verifies the method is effective and feasible.关键词
符号有向图(SDG)/模糊符号有向图(SDG)/模糊阈值/模糊推理Key words
Signed Directed Graph/fuzzy Signed Directed Graph(SDG)/fuzzy threshold/fuzzy reasoning分类