电力系统自动化2011,Vol.35Issue(8):58-62,5.
基于相关分析的同杆双回线突变量选相新方法
Fault Phase Selection with Fault Component in Same-tower Double-circuit Lines Based on Correlation Analysis
摘要
Abstract
In order to select the fault phase in same-tower double-circuit lines, a new fault phase selector is proposed with the analysis on the fault currents in the same phase of double-circuit line. Combining correlation analysis on the same phase currents with the amplitude of fault component, phase selection can be implemented. The algorithm is simple and fast. It can accomplish phase selection rapidly within half cycle. It also has good robustness so that it can be combined with existing distance protection easily. Computer simulation results show that the fault phase selector can solve the phase selection problem of the same-tower double-circuit lines effectively.关键词
故障选相/同杆并架双回线/突变量/相关分析/自适应/电力系统Key words
fault phase selection/same-tower double-circuit line/fault component/correlation analysis/adaptive/power systems引用本文复制引用
李伟,毕天姝,杨奇逊..基于相关分析的同杆双回线突变量选相新方法[J].电力系统自动化,2011,35(8):58-62,5.基金项目
国家自然科学基金重点项目(50837002) (50837002)
国家自然科学基金重大国际合作项目(50920105705) (50920105705)
高等学校学科创新引智计划(B08013) (B08013)
国家重点基础研究发展计划(973计划)资助项目(2009CB219704) (973计划)