| 注册
首页|期刊导航|中国组织工程研究与临床康复|四种超硬石膏模型精度及抗弯强度的比较

四种超硬石膏模型精度及抗弯强度的比较

雷东辉 杨建军 安世昌 李晓飞 付彤晓 王春方

中国组织工程研究与临床康复2011,Vol.15Issue(21):3979-3982,4.
中国组织工程研究与临床康复2011,Vol.15Issue(21):3979-3982,4.DOI:10.3969/j.issn.1673-8225.2011.21.043

四种超硬石膏模型精度及抗弯强度的比较

Comparisons of dimensional accuracy and bending resistance among four kinds of super-hard plaster casts

雷东辉 1杨建军 2安世昌 2李晓飞 1付彤晓 1王春方1

作者信息

  • 1. 青岛大学医学院附属医院口腔修复科,山东省青岛市,266000
  • 2. 青岛大学医学院附属医院口腔颌面外科,山东省青岛市,266000
  • 折叠

摘要

Abstract

BACKGROUND: In the clinic, super-hard plaster is widely used for preparation of casts that can duplicate oral cavity situation, such as fixed denture and removable denture. The bending resistance of super-hard plaster can sufficiently resist the force to strip, which would avoid the fracture of tooth model. However, the symptom of tooth model fracture exists when hard material, such as polyether rubber, is used as impression material. OBJECTIVE: To compare the dimensional accuracy and bending resistance among four kinds of super-hard plaster: YCG, Dentona, Heraeus, and Huicheng. METHODS: Mental casts including three unit fixed bridge and cuboid (50 mm×10 mm×5 mm) were prepared and then poured with the above-mentioned four kinds of super-hard plaster. Then dimensional accuracy and bending resistance of the casts were measured through the use of universal tool microscope and universal testing machine. CONCLUSION AND RESULTS: The proximal-distal dimensional accuracy of YCG, Dentona, Heraeus, and Huicheng super-hard plaster casts was 15.043, 15.034, 15.037 and 15.040 mm, respectively, the buccolingual dimensional accuracy was 7.020, 7.015, 7.019, and 7.019 mm, respectively, the tooth long-axis dimensional accuracy was 8.022, 8.018, 8.019, and 8.02 mm, respectively. The bending resistance of the four super-hard plaster casts was 15.687, 13.000, 22.521, 18.675 MPa, respectively. There was no significant difference in dimensional accuracy (P > 0.05), but there was significant difference in bending resistance (P < 0.01), among these four super-hard plaster casts. The bending resistance of Heraeus super-hard plaster cast was significantly greater compared with the other 3 super-hard plaster casts (P < 0.01), and the bending resistance of Huicheng super-hard plaster cast was significantly greater than that of Dentona super-hard plaster cast (P < 0.01). These findings demonstrate that Heraeus super-hard plaster has the highest bending resistance, followed by Huicheng and YCG super-hard plaster casts, and lastly Dentona super-hard plaster cast. These findings suggest that super-hard plaster cast with greater bending resistance should be chosen as possible according to practical situation.

关键词

超硬石膏/尺寸精度/抗弯强度/工作模型/口腔生物材料

分类

医药卫生

引用本文复制引用

雷东辉,杨建军,安世昌,李晓飞,付彤晓,王春方..四种超硬石膏模型精度及抗弯强度的比较[J].中国组织工程研究与临床康复,2011,15(21):3979-3982,4.

中国组织工程研究与临床康复

OACSCDCSTPCD

2095-4344

访问量4
|
下载量0
段落导航相关论文