强激光与粒子束2011,Vol.23Issue(5):1187-1192,6.DOI:10.3788/HPLPB20112305.1187
长时热变形下硅反射镜的参量选择
Parameters design of silicon reflectors in long-time thermal distortion
摘要
Abstract
The paper investigates the output characteristics of a chemical oxygen iodine laser(COIL) affected by nonideal resonator mirrors. Various parameters in long-time thermal deformation of silicon mirrors, such as absorption factor, supporting radius, and thermal load, are considered. The simulation results show that the absorption of mirrors plays a key role in beam quality control. If the decrease in laser output power is required to be less than 20% within the working time of 10 s, the absorption factor must be no more than 3.0 × 10-4. Furthermore, the beam size affects the supporting radius of four-point supporting. The additional phase aberration induced by mirror supporting deformation can be avoided as the supporting radius is greater than 1.4 times of the beam radius.关键词
反射镜/热变形/光强/相位/输出功率Key words
reflector/ thermal distortion/ intensity/ phase/ output power分类
信息技术与安全科学引用本文复制引用
杜燕贻,安建祝,束小建..长时热变形下硅反射镜的参量选择[J].强激光与粒子束,2011,23(5):1187-1192,6.基金项目
中国工程物理研究院科学技术基金项目(20060431) (20060431)