强激光与粒子束2011,Vol.23Issue(5):1207-1210,4.DOI:10.3788/HPLPB20112305.1207
化学激光器喷注器的流量标定
Flow rate calibration on injectors of chemical laser
闫宝珠 1袁圣付 1毛海峰1
作者信息
- 1. 国防科学技术大学,光电科学与工程学院,长沙,410073
- 折叠
摘要
Abstract
To provide references for the design of injectors in the combustion-driven continuous wave DF/HF chemical laser,five injectors of different structure were calibrated on flow rate by original criterion (mass-time method). Moreover, the results were explained reasonably by boundary-layer theory. The results show that the flow coefficient increases with the increase of the inlet pressure, and varies from 0. 677 to 0. 772. At the same condition of inlet pressure, the flow coefficient increases with the diameter and decreases with the length of the orifice. The flow coefficient of the slanting orifice is slightly smaller than the normal one with the same dimension.关键词
化学激光器/喷注器/流量标定/流量系数Key words
chemical laser/ rejector/ flow rate calibration/ flow coefficient分类
信息技术与安全科学引用本文复制引用
闫宝珠,袁圣付,毛海峰..化学激光器喷注器的流量标定[J].强激光与粒子束,2011,23(5):1207-1210,4.