原子能科学技术2011,Vol.45Issue(3):302-306,5.
中国百万千瓦级核电站严重事故下堆芯损伤评价
Core Damage Assessment for Chinese 1 000 MWe NPP Under Severe Accident Conditions
魏玮 1周志伟2
作者信息
- 1. 中国核电工程有限公司,北京,100840
- 2. 清华大学核能与新能源技术研究院,北京,100084
- 折叠
摘要
Abstract
By simulation analysis with the integral severe accident analysis code MELCOR1.8.5, the applicability of the Westinghouse Owners Group Core Damage Assessment Guidance (CDAG) to estimate the status and extent of the core damage in the early phase of the accident for a typical Chinese 1 000 MWe NPP was investigated. The preliminary analysis results show that CDAG can reasonably evaluate the core damage status and extent for the 1 000 MWe NPP in a loss of coolant accident (LOCA) without mitigation measures. The insights gained from the present study are of significant values for further studing and validating the comprehensive assessment capability and applicability of the CDAG, and for advancing the establishment of the severe accident management guidelines (SAMGs) of existing plants in China.关键词
堆芯损伤评价/严重事故/MELCOR程序/冷却剂丧失事故分类
通用工业技术引用本文复制引用
魏玮,周志伟..中国百万千瓦级核电站严重事故下堆芯损伤评价[J].原子能科学技术,2011,45(3):302-306,5.