原子能科学技术2011,Vol.45Issue(3):356-359,4.
17F+P共振态弹性散射实验中PPAC性能测试
Capability of PPAC in Investigation of Resonant Properties in 18Ne via 17F+p
摘要
Abstract
A parallel plate avalanche counter (PPAC) with delay-line readout was designed to be used in the experiment of investigation of resonant properties in 18 Ne via 17F+p. The position resolution, time resolution, and detection efficiencies of PPAC were researched in detail. The results of analysis show that 1 mm position resolution, 0.29 ns time resolution, and 97% detection efficiencies are achieved.关键词
位置灵敏平行板雪崩探测器/延迟线读出法/位置分辨/时间分辨/探测效率分类
能源科技引用本文复制引用
马朋,胡正国,张雪荧,杨彦云,李祖玉,张金霞,鲁辰桂,王建松,段利敏,耿朋,唐述文,鲁皖,梅波,严鑫帅..17F+P共振态弹性散射实验中PPAC性能测试[J].原子能科学技术,2011,45(3):356-359,4.基金项目
中国科学院知识创新工程资助项目(KJCXI-YW-004,YFKJCX3.SYW.N5) (KJCXI-YW-004,YFKJCX3.SYW.N5)
国家重点基础研究发展计划资助项目(2008CB817702) (2008CB817702)
国家自然科学联合资助基金资助项目(10979064) (10979064)