强激光与粒子束2011,Vol.23Issue(3):849-852,4.DOI:10.3788/HPLPB20112303.0849
孔缝腔体内多导体传输线的耦合响应
Coupling onto wires enclosed in cavity with aperture
摘要
Abstract
The main objective of this work is to study the computation of coupling on wires enclosed in the cavity with apertures by exciting sources. The analytical approach is rigorous and slow implementations. The numerical technique is too approximate to be useful. This paper presents a semi-analytical and semi-numerical approach based on method of moments-Green's function(MoM-GF) technique and BLT equation. The MoM-GF technique is sufficiently accurate to simulate the equivalent magnetic flux to give the electromagnetic field in the cavity. And the formulas to compute the induced voltage and induced current of the two wire lines, terminations are derived employing the BLT equation based on Taylor model. The simulation on electric field shielding effectiveness of the cavity with apertures is conducted, which validates the semi-analytical and semi-numerical approach. The coupling voltage and current are also numerically calculated.关键词
孔缝腔体/孔缝耦合/多导体传输线/数值计算/Taylor模型Key words
cavity with aperture/aperture eoupling/transmission lines/numerical simulation/Taylor model分类
信息技术与安全科学引用本文复制引用
史记元,罗建书,倪谷炎,李颖,陈小平..孔缝腔体内多导体传输线的耦合响应[J].强激光与粒子束,2011,23(3):849-852,4.基金项目
国家自然科学基金项目(10871231) (10871231)
中国博士后科学基金项目(20080431399) (20080431399)