摘要

Abstract

Diagnosing conditions of compressed fuel is a critical aspect of ICF capsule implosion experiments. A common diagnostic technique is to add a small concentration of high- or mid-Z dopant to the fuel, and measure the emission from the dopant either spectroscopically or by imaging. With radiative hydrodynamic simulations and post-processing of X-ray imaging for implosions, the designs of the fuel capsule are optimized, and the effects of tracer in fuel on X-ray diagnostics of implosion are analyzed.The results show that for the capsule of D2 fuel doped with argon at about l% atomic fraction, although the implosion yield reduces by about 15%, the X-ray intensity of fuel increases by 50 times and the size of X-ray imaging is enlarged by about 30%,which is beneficial to the diagnosis of the fuel core. For the capsule with 0.05μm thick sulfur coated inside the CH shell, the dimensions of sulfur Ly-α monochromatic X-ray imaging accord with those of the fuel region, and thus the compressed boundary of fuel can be deduced. Above analysis results have been validated by Shenguang Ⅱ implosion experiments.

关键词

激光聚变/内爆/示踪元素/燃料界面/X光诊断

Key words

laser fusion/ implosion/ tracer/ fuel boundary/ X-ray diagnostics

分类

数理科学

引用本文复制引用

高耀明,李蒙,李永升,康洞国,李沄生..示踪材料在内爆X光诊断过程中的作用[J].强激光与粒子束,2011,23(3):693-696,4.

基金项目

国家自然科学基金项目(10975025) (10975025)

计算物理实验室基金项目 ()

国家高技术发展计划项目 ()

强激光与粒子束

OA北大核心CSCDCSTPCD

1001-4322

访问量0
|
下载量0
段落导航相关论文