| 注册
首页|期刊导航|中华医学杂志(英文版)|Comparison of FP-7 and S-2 Ahmed glaucoma valve implantation in refractory glaucoma patients for short-term follow-up

Comparison of FP-7 and S-2 Ahmed glaucoma valve implantation in refractory glaucoma patients for short-term follow-up

BAI Yu-jing LI Yi-qing CHAI Fang YANG Xue-jiao ZHANG Yi-chong WEI Yan-tao HUANG Jing-jing GE Jian ZHUO Ye-hong

中华医学杂志(英文版)2011,Vol.124Issue(8):1128-1133,6.
中华医学杂志(英文版)2011,Vol.124Issue(8):1128-1133,6.DOI:10.3760/cma.j.issn.0366-6999.2011.08.002

Comparison of FP-7 and S-2 Ahmed glaucoma valve implantation in refractory glaucoma patients for short-term follow-up

Comparison of FP-7 and S-2 Ahmed glaucoma valve implantation in refractory glaucoma patients for short-term follow-up

BAI Yu-jing 1LI Yi-qing 1CHAI Fang 1YANG Xue-jiao 1ZHANG Yi-chong 1WEI Yan-tao 1HUANG Jing-jing 1GE Jian 1ZHUO Ye-hong1

作者信息

  • 折叠

摘要

Abstract

Background Ahmed glaucoma valves (AGV) has been used for decades, but there is no detailed report about the efficacy of AGV in Chinese glaucoma patients. This study aimed to compare the intraocular pressure (IOP) lowering efficacy and side effects of S-2 polypropylene and PF-7 silicone AGV implantation in Chinese refractory glaucoma patients.Methods Patients were divided into S-2 model AGV group and FP-7 model AGV group. The complete and qualified surgical success rate, change of IOP, number of anti-glaucoma medications used and postoperative complications were recorded and analyzed.Results Average follow-up time was comparable between two groups. IOP was reduced from (37.9±12.7) mmHg preoperatively to (17.3±5.3) mmHg at the last follow-up in S-2 group and reduced from (39.9±14.4) mmHg to (17.7±4.9)mmHg in FP-7 group. Anti-glaucoma medications were reduced from 3.8±0.2 to 1.5±0.2 in S-2 group, and 3.5±0.2 to 0.7±0.2 in FP-7 groups. The cumulative success rates were comparable in two groups, which were 61.2% and 72.1% in S-2 group and FP-7 group respectively. When IOP reduction criteria was used, complete success rates were 30.6% and 51.2% for S-2 and FP-7 groups, and qualified success rates were 86.1% and 92.7% separately. In both groups, the major complication was hypotony, and the previous trabeculectomy of patients was the major risk factor for surgery failure.Conclusions In this short-term retrospective study, S-2 AGV is showed at least as effective as FP-7 AGV in IOP reduction, but associated with higher rate of complications. Previous trabeculectomy is a principle risk factor for AGV implantation failure. These clinical outcomes are important for converting use of the FP-7 silicon AGV in Chinese refractory glaucoma patients.

关键词

glaucoma, drainage device/Ahmed/refractor glaucoma

Key words

glaucoma, drainage device/Ahmed/refractor glaucoma

引用本文复制引用

BAI Yu-jing,LI Yi-qing,CHAI Fang,YANG Xue-jiao,ZHANG Yi-chong,WEI Yan-tao,HUANG Jing-jing,GE Jian ,ZHUO Ye-hong..Comparison of FP-7 and S-2 Ahmed glaucoma valve implantation in refractory glaucoma patients for short-term follow-up[J].中华医学杂志(英文版),2011,124(8):1128-1133,6.

基金项目

This work was supported by the grants from the National Basic Research Program of China ("973" Program,No.2007CB512200),the National Natural Science Foundation of China (No.30872832,No.30700928),Guangdong Province Universities and Colleges 2010 Pearl River Scholar Funded Scheme and the Science and Technology Planning Project of Guangdong Province,China (No.2008B030301116). ("973" Program,No.2007CB512200)