医疗卫生装备2011,Vol.32Issue(2):60-61,2.
垂体MR图像质量控制及扫描方式的研究
Quality Control and Scanning Method of Pituitary MR Image
彭俊玲1
作者信息
- 1. 541002,广西桂林,广西壮族自治区南溪山医院影像科
- 折叠
摘要
Abstract
Objective To explore the ideal pituitary MR examination methods in order to improve the pituitary MRI scan image quality. Methods 40 patients with suspected anterior pituitary adenomas were selected as volunteers for MR scanning images, which was divided into four groups, including A group without saturation technology and B group with saturation technology of SE sequence, and A1 group without saturation technology and A2 group with saturation technology of FE sequence. The anatomical structure and detail of the pituitary and the around tissue were displayed and evaluated. The display quality was divided into three levels: excellent, good and bad by SPSS for data analysis. Results FE sequence with saturation technology could show the pituitary gland and relevant anatomy clearly. Scanning method of B1 group was compared with conventional group and A1 group. The quality of image was improved obviously, with p<0.05. Conclsion Using FE and saturation technology can improve the quality of image, shorten working hours, and improve work efficiency.关键词
垂体/磁共振成像/扫描方式分类
医药卫生引用本文复制引用
彭俊玲..垂体MR图像质量控制及扫描方式的研究[J].医疗卫生装备,2011,32(2):60-61,2.