中国电力2011,Vol.44Issue(4):45-49,5.
CCI旁路系统在600MW直接空冷机组的应用
Application of CCI bypass systems in 600 MW direct air cooling unit
李铁苍 1温源2
作者信息
- 1. 山西电力职业技术学院,山西,太原,030021
- 2. 国电电力大同发电有限责任公司,山西,大同,037043
- 折叠
摘要
Abstract
The configuration of the main equipment and by pass control system equipment of 2×600 MW direct air cooling units in Datong Power Generation Co.,Ltd,was introduced .The mode and characteristics of unit operation ,as well as the main functions of bypass control system were analyzed briefly ,Based on the using methos of the bypass system and the actual operation in a year,the operation method of bypas scontrol system coordinated with turbine,boilers,generator and air cooling system during the high-pressure cylinder startup and high & medium pressure united startup in direct air cooling unit was claborated.The shortage of the current system was pointed out ,and the improving syggestions were gained.关键词
直接空冷机组/旁路系统/设备配置/功能特点/运行模式分类
能源科技引用本文复制引用
李铁苍,温源..CCI旁路系统在600MW直接空冷机组的应用[J].中国电力,2011,44(4):45-49,5.