摘要

Abstract

A gas chromatography - positive chemical ionization mass spectrometric ( CC - PCI/MS)method was developed for the determination of migration levels of 7 N-nitrosamines and N-nitrosatable substances including N-nitrosodimethylamine ( NDMA), N-nitrosodiethylamine ( NDEA ), N-nitrosodi-n-propylamine ( NDPA), N-nitrosodi-n-butylamine ( NDBA ), N-nitrosopiperidine ( NPIP), N-nitrosopyrrolidine(NPYR) and N-nitrosomorpholine (NMOR) from household rubber gloves by using Sep-Pak AC2 connecting to Sep-Pak Dry cartridges. The developed method was simple, rapid, sensitive and accurate. Its quantitation limits for N-nitrosamines and N-nitrosatable substances were 1.25 μg/kg and 5.0 μg/kg, respectively. The total release values for the 7 N-nitrosatable substances were 6. 96- 168. 46 μg/kg, in which NDEA, NDMA and NDBA were found most frequently in 13 analysed household rubber gloves. The risk exposure levels of seven N-nitrosamines from household rubber gloves were in the class of 1.81 -43.80 μg per person in a year, which would bring a potent tial risk to people, especailly to some occupational population.

关键词

气相色谱-正化学源/质谱法/手套/N-亚硝胺/前体物/迁移量

Key words

gas chromatography - positive chemical ionization mass spectrometry ( GC - PCI/MS)/gloves/ N-nitrosamines/ N-nitrosatable substances/ migration level

分类

化学化工

引用本文复制引用

幸苑娜,王欣,陈泽勇,黄锦敏..气相色谱-正化学源质谱法测定家用橡胶手套中7种N-亚硝胺及其前体物的迁移量[J].分析测试学报,2011,30(5):503-508,6.

基金项目

广东省质量技术监督局科技资助项目(2010CZ10) (2010CZ10)

分析测试学报

OA北大核心CSCDCSTPCD

1004-4957

访问量2
|
下载量0
段落导航相关论文