| 注册
首页|期刊导航|测试技术学报|引信双球转子远解机构试验测试与仿真研究

引信双球转子远解机构试验测试与仿真研究

龚玉帅 焦国太 邓光明 李晓晨

测试技术学报2011,Vol.25Issue(3):254-257,4.
测试技术学报2011,Vol.25Issue(3):254-257,4.DOI:10.3969/j.issn.1671-7449.2011.03.013

引信双球转子远解机构试验测试与仿真研究

Study on Experimental Measurement and Simulation of Fuze Double Ball Rotor Arming Delay Device

龚玉帅 1焦国太 1邓光明 1李晓晨2

作者信息

  • 1. 中北大学机电工程学院,山西太原030051
  • 2. 西安机电信息研究所,陕西西安710065
  • 折叠

摘要

Abstract

Because the delay arming time of ball rotor safety device is too short to satisfy the delay arming requirement of small-caliber fuze, a double ball rotor technique is put forward. The relay rotation of the spherical shell and ball rotor is under the control of a dowel pin, which extends the delay arming distance. The feasibility of the device and the reasonableness of the simulation model were verified by experiment. The dynamic simulation of the double ball rotor device was completed by using the software of ADAMS. In a specific trajetory environment, the delay arming distance is 49. 455 m, which can satisfy the requirement of safety design guidelines for fuze.

关键词

小口径引信/双球转子/延期解除保险/仿真

Key words

small-caliber fuze/ double ball rotor/ delay arming/ simulation