电力系统自动化2011,Vol.35Issue(1):18-22,28,6.
计及电网变化过程的地区电网运行风险评估
Identification of Critical Lines in Restoration Scheme for Transmission Network
摘要
Abstract
After large-scale blackout, if certain critical lines fail to operate in the process of restoration scheme owing to the external environment or weak links in the lines themselves, the restoration process will be seriously affected. By referring to the above-mentioned failure, a relative line betweenness is defined employing the concept of betweenness from the complex network theory. Furthermore, a critical degree of lines is put forward to identify the critical lines in the restoration scheme for the transmission network. An analysis is made on the IEEE 30-bus system to identify the critical lines in the restoration scheme. The results show that the index proposed can effectively identify critical lines that are of high availability and markedly influence the restoration result under definite restoration principles. The method proposed is of practical significance in guiding the process of restoration.关键词
地区电网/风险评估/运行风险/电网变化过程Key words
blackout/ black start/ transmission network reconfiguration/ critical line/ betweenness/ vulnerability assessment for power grid引用本文复制引用
汪隆君,李博,王钢,胡子珩,何晓峰..计及电网变化过程的地区电网运行风险评估[J].电力系统自动化,2011,35(1):18-22,28,6.基金项目