河南农业大学学报2011,Vol.45Issue(2):201-203,3.
主动式太阳房的设计与试验
Design and experiment of active solar house
摘要
Abstract
The cooling, heating dual-use of active solar house was designed, and its effect was aslo tested. The results showed that the temperature of the experimenting room was generally 7.28 ℃ higher than that of the contrasted room in winter heating, with the maximum temperature difference reaching 10 ℃, and the minimum only 5.60 ℃. While, the average temperature in active solar house was lower than that of the contrasted room by 4.83 ℃ in the summer cooling experiment, and the maximum temperature difference was 7.80 ℃ and the lowest was 1.50 ℃.关键词
主动式太阳房/地下冷水/对流换热Key words
active solar house/ underground cols water/ convection heat transfer分类
农业科技引用本文复制引用
梁盼,刘圣勇,孙兵兵,邹会发,华磊,刘亮..主动式太阳房的设计与试验[J].河南农业大学学报,2011,45(2):201-203,3.基金项目
河南省重点基础与前沿技术研究计划项目(082300433205) (082300433205)