Abstract

A smart capsule for drug delivery based on a pH sensor was proposed here. The system can automatically identify the pH changes of the gastrointestinal (GI) tract, and then it can automatically release the drug if the pH changes satisfy the established procedure. A pH measuring module in this system was designed here. The pH measuring module consists of pH sensor module, measuring circuit module, microprocessor chip module, and power management module. The performances of pH measuring module and pH sensors were tested in vitro experiments. The experimental results showed that the sensitivity of pH sensor was 43.5 mV/pH, which met the need of pH measuring in the GI tract. Additionally,when the trigger voltage stored in the micro controller unit( MCU)was from 113.1 to 282.8 mV, the capsule could release the medicine in the esophagus, stomach and intestinal tract accurately according to the change of pH value.

关键词

MEMS技术/智能释药胶囊/pH传感器/微处理器芯片

Key words

MEMS/ smart delivery capsule/ pH sensors/ microprocessor chips

分类

医药卫生

引用本文复制引用

李晓华,刘洪英,贾子如,皮喜田,郑小林,彭承琳,温志渝..智能释药胶囊内酸碱度测量模块的设计[J].传感技术学报,2011,24(4):492-497,6.

基金项目

国家自然科学基金项目(30700160,30970883) (30700160,30970883)

中国博士后科学基金项目(20070420718,200801225) (20070420718,200801225)

教育部高等学校博士学科点科研基金项目(20070611045) (20070611045)

重庆大学研究生创新基金项目(200801A1B0250248) (200801A1B0250248)

传感技术学报

OA北大核心CSCDCSTPCD

1004-1699

访问量0
|
下载量0
段落导航相关论文