| 注册
首页|期刊导航|物理学报|透射光栅的实验标定和衍射效率的理论模拟

透射光栅的实验标定和衍射效率的理论模拟

尚万里 杨家敏 赵屹东 崔明启 郑雷 韩勇 周克瑾 马陈燕 朱托 熊刚 赵阳 张文海 易荣清 况龙钰 曹磊峰 高宇林

物理学报2011,Vol.60Issue(3):330-335,6.
物理学报2011,Vol.60Issue(3):330-335,6.

透射光栅的实验标定和衍射效率的理论模拟

Experimental calibration of transmission grating and theoretical calculation of diffraction efficiency

尚万里 1杨家敏 1赵屹东 2崔明启 2郑雷 2韩勇 2周克瑾 2马陈燕 2朱托 1熊刚 1赵阳 1张文海 1易荣清 1况龙钰 1曹磊峰 1高宇林1

作者信息

  • 1. 中国工程物理研究院激光聚变研究中心,绵阳621900
  • 2. 中国科学院高能物理研究所,北京100049
  • 折叠

摘要

Abstract

Transmission grating is widely used in measurement of soft X rays. In order to measure the diffraction efficiencies of the transmission grating which is used in laser fusion, the transmission grating was calibrated on Beijing Synchrotron Radiation Facility in the energy region from 200eV to 1600eV, and the experimental results have been obtained. The model for grating efficiency simulation has been developed and calculations using a new so called 7-side quasi-trapezoidal cross section model were carried out. The results from the new model are in good agreement with the experimental data.The exact grating wire cross section is described.

关键词

透射光栅/衍射效率/实验标定/光栅模型

Key words

transmission grating/ diffraction efficiency/ experimental calibration/ grating model