压力容器2011,Vol.28Issue(4):12-17,6.DOI:10.3969/j.issn.1001-4837.2011.04.003
高真空多层绝热低温容器完全真空丧失后升压规律的试验研究
Experimental Investigation of the Pressure Rise Progress of HVMLI Cryogenic Tanks after Catastrophic Loss of Insulating Vacuum
谢高峰 1汪荣顺 1魏蔚1
作者信息
- 1. 上海交通大学制冷及低温工程研究所,上海,200240
- 折叠
摘要
Abstract
High - vacuum - multilayer - insulation ( HVMLI) cryogenic tank is a kind of dangerous pressure vessel. One of the worst accidents that may occur in a HVMLI cryogenic tank is a sudden, catastrophic loss of insulation vacuum ( SCLIV ). The influence of SCLIV on storage performance for a HVMLI cryogenic tank is experimentally studied. A test rig was built up and experiments were conducted using LN2 as the test medium. The cryogenic tank was tested in the conditions of various combinations with different initial filling rate and number of insulation layers. Some important conclusions for storage performance with a vacuum - lost HVMLI cryogenic tank have been obtained. The experimental results show that the numbers of insulation layers and the initial filling rate have obvious effect on the storage performance after SCLIV for cryogenic tanks.关键词
高真空多层绝热低温容器/完全的真空丧失/绝热材料层数/初始充满率Key words
high - vacuum - multilayer - insulation ( HVMLI) cryogenic tank/ sudden loss of insulation vacuum/ insulation layers/ initial filling rate分类
通用工业技术引用本文复制引用